Series IEF Insertion Electromagnetic Flow Transmitter

Views: 1606

P/N#: IEF, IEF-HN-CND-LCD-CC, IEF-GB-PG-COM, IEF-GN-CND-COM-LCD, IEF-LB-PG-COM, IEF-LN-CND-COM-LCD, IEF-SB-PG-LCD, IEF-SN-CND, IEF-SN-CND-LCD

Origin:

The Series IEF Insertion Electromagnetic Flow Transmitter is an adjustable insertion flowmeter featuring electromagnetic technology that accurately and reliably measures fluid velocity in addition to providing several continuous signal outputs. This series is specifically designed to offer superior performance paired with simple installation and use. One unit is adjustable to fit pipe sizes from 4 to 36" (101.6 to 914.4 mm), and offers several output options including selectable BACnet MS/TP or Modbus® RTU communications protocol over 2-wire RS-485 in addition to the standard analog, frequency and alarm outputs.

Request a quote

Contact
Service:
Compatible clean or dirty non coating, conductive liquids.
Range:
0 to 20 ft/s (0 to 6 m/s).
Wetted Materials:
Body shaft/fitting: 316SS; Electrodes: 316SS; Electrode cap: Polymer/Polystyrene; O-ring: Silicon.
Accuracy:
High accuracy units: ±0.5% of reading at calibrated velocity; ±1% of reading from 2 to 20 ft/s (0.6 to 6 m/s); ±0.02 ft/s (±0.006 m/s) at < 2 ft/s (0.6 m/s);
Standard accuracy units: ±1% FS.
Temperature Limits:
Ambient: -20 to 160°F (-29 to 71°C); Process: 15 to 250°F (-9 to 121°C); Storage: -40 to 185°F (-40 to 85°C).
Process Connection:
1" NPT or BSPT with accessory full port ball valve options.
Pressure Limits:
400 psi (27.6 bar) @ 100º F (37.8°C).
Pressure Drop:
< 0.1 psi at 12 ft/s in 4" (101.6 mm) and larger pipe.
Outputs:
(1) Analog: 4 to 20 mA, 0 to 5 V, 0 to 10 V or 2 to 10 V (display selectable);
(1) Pulse/Frequency: 0 to 15 V peak pulse, 0 to 500 Hz or scalable pulse output (display selectable);
(2) Alarm: (1) Empty pipe detection or minimum/maximum velocity, (display selectable);
(1) Reverse flow output indication.
Power Requirements:
12 to 42.4 VDC, .25 A @ 24 VDC; 12 to 36 VAC.
Electrical Connection:
Removable terminal blocks, model selectable 1/2" female NPT conduit connection, PG 16 gland or PG 16 gland with (2) 10' (3 m) 9 conductor 22 AWG plenum rated cables, accessory cable lengths up to 200' (61 m) optional.
Display:
2" ( 5.08 cm) x 2" (5.08 cm) graphic LCD with backlight.
Conductivity:
>20 microsiemens.
Enclosure Material:
Powder coated die cast aluminum.
Enclosure Ratings:
NEMA 6P (IP68) (Non display models); NEMA 4X (IP66) (-LCD option).
Agency Approvals:
BTL, CE, NSF/ANSI 61 and 372.

 

 
COMMUNICATIONS (-COM OPTION)
Type:
BACnet MS/TP or Modbus® RTU communication protocol (default disabled, display selectable).
Supported Baud Rates:
9600, 19200, 38400, 57600, 76800, or 115200 bps (display selectable).
Device Load:
1/8 unit load.

 

 
ADDITIONAL SPECIFICATIONS
Applicable Pipe Material:
Most popular plastic and metal pipes; i.e. Carbon steel, SS, copper, UPVC/PVDF, galvanized steel, mild steel, and brass*.
Applicable Pipe Size:
4 to 36" (100 to 900 mm), model dependent. See model chart on catalog page.
Diameter Length Requirements:
>10 upstream, >5 downstream.

 

Glycol:
0 to 100% display selectable.
 
*Brass fittings and pipe not for use with NSF Certified models.
Model Description
IEF-HN-CND-LCD-CC High accuracy 1% of reading, conduit connection, BACnet/Modbus® Communication output with LCD display custom configured for specified configuration      
IEF-GB-PG-COM Insertion Electromagnetic flow transmitter, 10-36" (250-900 MM) pipe, standard accuracy 1% FS, 1" male BSPT process connection, PG gland, BACnet/Modbus® output
IEF-GN-CND-COM-LCD Insertion Electromagnetic flow transmitter, 10-36" (250-900 MM) pipe, standard accuracy 1% FS, 1" male NPT process connection, 1/2" female NPT conduit connection, BACnet/Modbus® output, integral display
IEF-LB-PG-COM Insertion Electromagnetic flow transmitter, 4-10" (100-250 MM) pipe, standard accuracy 1% FS, 1" male BSPT process connection, PG gland, BACnet/Modbus® output
IEF-LN-CND-COM-LCD Insertion Electromagnetic flow transmitter, 4-10" (100-250 MM) pipe, standard accuracy 1% FS, 1" male NPT process connection, 1/2" female NPT conduit connection, BACnet/Modbus® output, integral display
IEF-SB-PG-LCD Insertion Electromagnetic flow transmitter, standard accuracy 1% FS, pg gland, integral LCD set up display
IEF-SN-CND Insertion Electromagnetic flow transmitter, standard accuracy 1% FS, conduit connection
IEF-SN-CND-COM Insertion Electromagnetic flow transmitter, standard accuracy 1% FS, conduit connection with BACnet/Modbus® communication output
IEF-SN-CND-COM-LCD Insertion Electromagnetic flow transmitter, standard accuracy 1% FS, conduit connection with BACnet/Modbus® communication output with LCD display
IEF-SN-CND-LCD Insertion Electromagnetic flow transmitter, standard accuracy 1% FS, conduit connection, integral LCD set up display