The UNI MP100 offers a simple portable solution for the widest array of toxic gas and oxygen (O2) applications on the market. In addition to typical sensors such as carbon monoxide (CO), hydrogen sulfide (H2S), nitrogen (NOx), ammonia (NH3) and sulfur dioxide (SO2), we offer less-common sensors including hydrogen chloride, phosphine, ozone, ethylene oxide, methyl mercaptan, arsine and phosgene. The monitors have a large LCD providing maximum readability in the field and are made with six bright red LEDs allowing for a quick alarm notification. Constructed of strong and durable material, the UNI is designed to be comfortable yet drop-resistant. The UNI series can easily be bump tested and calibrated either manually or using the convenient Single Docking Box, or CaliCase for up to 4 units at a time.
- Size: 3.46 x 2.44 x 1.3 in (88 x 62 x 33 mm) Weight: 4.4 oz (125 g)
- UL/cUL: Class I, Div 1, Group A, B, C, D; Class II, Div 1, Group E, F, G; Class III, Div 1
- Temperature rating T4, -20°C ≤ Tamb ≤ +50°C
- Event logger
- IP rating: IP-67
- Large LCD, 30% larger than most
- Password protection
- Adjustable Low, High, TWA & STEL alarms
- Six bright red flashing LEDs
- Sensors for over 20 chemicals in 30 concentration ranges
- Two-point field calibration
- 3-year typical operation
Size |
3.46 x 2.44 x 1.3 in
(88 x 62 x 33 mm) |
Weight |
4.4 oz (125 g) |
Temperature |
-4°F to 122°F (-20°C to 50°C) |
Humidity |
5 to 95% relative humidity (non-condensing) |
Alarm Type |
High alarm, Low alarm, STEL alarm, TWA alarm, adjustable.
Over-range alarm, Battery low alarm |
Alarm Signal |
95 dB @ 30 cm audible
Bright red LED
Built in vibrator |
Calibration |
2 point calibration, zero and span, power on zero (user-selectable) |
Event log |
Up to 50 alarm events |
Response time (t90) |
15 seconds (CO/H2S/O2), Others vary, see individual sensor specifications in TA Note 4 |
IP rating |
IP-67 |
EMI/RFI |
Compliant with EMC 2004/108/EC |
Safety certifications |
IECEx Ex ia IIC T4 Ga
ATEX CE Ex II 1G
Ex ia IIC T4 Ga
UL/cUL
Class I, Div 1, Group A, B, C, D
Class II, Div 1, Group E, F, G
Class III, Div 1
T4, -20°C ≤ Tamb ≤ +50°C
|
Battery |
Replaceable AA size Lithium battery, 3 years typical operation |
Sensor |
CO/H2S expected operating life 5 years or longer, others 1 to 2 years as per warranty |
Warranty |
2 years on O2, CO, H2S, SO2, HCN, NO, NO2, and PH3 units including sensor; 1 year on others |
Gas |
Measuring Range /
Resolution (ppm) |
Instrument
P/N |
CO |
500/1
1000/1
2000/1 |
M001-0002-000
M001-0023-000
M001-0026-000 |
H2S |
50.0/0.1
100.0/0.1
200.0/0.1
1000/1 |
M001-0003-000
M001-0054-000
M001-0057-000
M001-0060-000 |
O2 |
25.0/0.1%
30.0/0.1% |
M001-0032-000
M001-0001-000 |
O2 Lead-free |
25.0/0.1%
30.0/0.1% |
M001-0094-000
M001-0095-000 |
O2 Inverted Alarm for Inert |
25.0/0.1% |
M001-0093-000 |
H2 |
1000/1
2000/1 |
M001-0018-000
M001-0019-000 |
NH3 |
50/1 |
M001-0006-000 |
NH3 |
500/1 |
M001-0090-000 |
Cl2 |
50.0/0.1 |
M001-0004-000 |
ClO2 |
1.00/0.01 |
M001-0072-000 |
HCN |
100/0.1 |
M001-0005-000 |
NO |
250/1 |
M001-0015-000 |
NO2 |
20.0/0.1 |
M001-0011-000 |
PH3 |
20.0/0.01 |
M001-0016-000 |
SO2 |
20.0/0.1 |
M001-0007-000 |
SO2 |
100.0/0.1 |
M001-0091-000 |
Ethylene Oxide (ETO) |
100.0/0.1
200.0/0.1 |
M001-0012-000
M001-0069-000 |
O3 |
5.00/0.01 |
M001-0009-000 |
HF |
10.0/0.1 |
M001-0014-000 |
HCl |
15.0/0.1 |
M001-0008-000 |
CH3SH |
10.0/0.1 |
M001-0077-000 |
Acetaldehyde (C2H4O) |
20.0/0.1 |
M001-0080-000 |
Tetrahydrothiophene (THT) |
40.0/0.1 |
M001-0085-000 |
Arsine (AsH3) |
1.0/0.01 |
M001-0092-000 |
Phosgene (COCl2) |
1.0/0.01 |
M001-0020-000 |